In a unique endeavor, IKA owner René Stiegelmann has partnered up with Professor Phil S. Baran of the world-renowned Scripps Research Institute in La Jolla, California (USA). Over the past three years, engineers and chemists have worked hand in hand to develop a product combining two divisions of chemistry communities: the Electrochemistry and the mainstream Synthetic Organic Chemistry Communities that traditionally don’t have much in common.
ElectraSyn 2.0 essentially combines three products in one and will facilitate the mass adoption of electrochemistry for preparative organic synthesis: a potentiostat, an analytical device and a stir plate. It is a compact, user friendly and cost effective platform for organic chemists to explore electrochemistry.
The ElectraSyn 2.0 Ready-To-Go package includes all that is required to for your first experiment. including a single 10 ml vial (complete), vial holder and a set of electrodes (graphite).
ElectraSyn 2.0 offers:
standardization
analytical capabilities
modularity
user-friendly interface
stirring abilities
future proofing
industry-leading display
aesthetic design
connectivity
ElectraSyn 2.0 app
ease of transportation
Accessories are also available, including a carousel which enables six reactions in parallel, electrodes of various materials and sizes, and vials from 1 to 20 ml.
The IKA ElectraSyn App (available for both iPhone and Android) enables reaction and CV experiment monitoring, data transmitting, and various other functions. ElectraSyn is a device that improves over time through regular software updates.
Scope of delivery
ElectraSyn 2.0 Package
Single vial holder
Single vial, 10 ml, complete
Electrodes (graphite) (2x)
Stir plate
$$$$$
Nominal voltage (input)
48 VDC
Current max. (input)
1500 mA
Voltage output (electrode)
30/10 V
Current output (electrode)
100 mA
Motor rating output
9 W
Speed range
50 - 1500 rpm
Setting accuracy speed
10 rpm
Stirring quantity max. per stirring position (H2O)
In a unique endeavor, IKA owner René Stiegelmann has partnered up with Professor Phil S. Baran of the world-renowned Scripps Research Institute in La Jolla, California (USA). Over the past three years, engineers and chemists have worked hand in hand to develop a product combining two divisions of chemistry communities: the Electrochemistry and the mainstream Synthetic Organic Chemistry Communities that traditionally don’t have much in common.
ElectraSyn 2.0 essentially combines three products in one and will facilitate the mass adoption of electrochemistry for preparative organic synthesis: a potentiostat, an analytical device and a stir plate. It is a compact, user friendly and cost effective platform for organic chemists to explore electrochemistry.
The ElectraSyn 2.0 Ready-To-Go package includes all that is required to for your first experiment. including a single 10 ml vial (complete), vial holder and a set of electrodes (graphite).
ElectraSyn 2.0 offers:
standardization
analytical capabilities
modularity
user-friendly interface
stirring abilities
future proofing
industry-leading display
aesthetic design
connectivity
ElectraSyn 2.0 app
ease of transportation
Accessories are also available, including a carousel which enables six reactions in parallel, electrodes of various materials and sizes, and vials from 1 to 20 ml.
The IKA ElectraSyn App (available for both iPhone and Android) enables reaction and CV experiment monitoring, data transmitting, and various other functions. ElectraSyn is a device that improves over time through regular software updates.
Scope of delivery
ElectraSyn 2.0 Package
Single vial holder
Single vial, 10 ml, complete
Electrodes (graphite) (2x)
Stir plate
$$$$$
Nominal voltage (input)
48 VDC
Current max. (input)
1500 mA
Voltage output (electrode)
30/10 V
Current output (electrode)
100 mA
Motor rating output
9 W
Speed range
50 - 1500 rpm
Setting accuracy speed
10 rpm
Stirring quantity max. per stirring position (H2O)
0.1 l
Stirring bar length
8 - 16 mm
Speed control
Turning knob
Display
TFT
Output current resolution
0.1 mA
Output voltage resolution
0.01 V
Current measuring resolution
0.1 mA
Voltage measuring resolution
0.1 V
Current measuring accuracy
0.1 ±mA
Voltage measuring accuracy
0.01 ±V
Dimensions (W x H x D)
130 x 150 x 250 mm
Weight
3.72 kg
Permissible ambient temperature
5 - 50 °C
Permissible relative humidity
80 %
Protection class according to DIN EN 60529
IP 40
USB interface
yes
Voltage
100 - 240 V
Frequency
50/60 Hz
Power input
39.84 W
Power input standby
5 W
DC Voltage
48 V=
Current consumption
750 mA
%%%%%
<tr style="background-
Documents for Qualification (IQ/ OQ) LAB
Proprietary Calibration Certificate/ LAB
IKA e-Hive
IKA Pro-Seal
IKA Pro-Divide
Calibration cap
IKA ElectraSyn GOGO Module
IKA Carousel complete
IKA Carousel
ElectraSyn Complete Vial Kit
ElectraSyn Electrode Starter Kit
ElectraSyn Vials Only
Electrode and Vial Starter Kit
ElectraSyn 2.0 MicroStarter Kit complete
ElectraSyn 2.0 MicroVial Kit complete
ElectraSyn 2.0 MicroVial Only Kit
ElectraSyn 2.0 MicroElectrode Starter Kit
Graphite electrode inner (24 pcs.)
Graphite electrode outer (24 pcs.)
Copper electrode outer (24 pcs.)
Copper electrode inner (24 pcs.)
Stainless electrode outer (24 pcs.)
Stainless electrode inner (24 pcs.)
CV Package
Graphite SK-50, Set of 12
Glassy carbon, Set of 2
Lead bronze, Set of 2
Lead, Set of 12
Tungsten, Set of 2
In a unique endeavor, IKA owner René Stiegelmann has partnered up with Professor Phil S. Baran of the world-renowned Scripps Research Institute in La Jolla, California (USA). Over the past three years, engineers and chemists have worked hand in hand to develop a product combining two divisions of chemistry communities: the Electrochemistry and the mainstream Synthetic Organic Chemistry Communities that traditionally don’t have much in common.
ElectraSyn 2.0 essentially combines three products in one and will facilitate the mass adoption of electrochemistry for preparative organic synthesis: a potentiostat, an analytical device and a stir plate. It is a compact, user friendly and cost effective platform for organic chemists to explore electrochemistry.
The ElectraSyn 2.0 Ready-To-Go package includes all that is required to for your first experiment. including a single 10 ml vial (complete), vial holder and a set of electrodes (graphite).
ElectraSyn 2.0 offers:
standardization
analytical capabilities
modularity
user-friendly interface
stirring abilities
future proofing
industry-leading display
aesthetic design
connectivity
ElectraSyn 2.0 app
ease of transportation
Accessories are also available, including a carousel which enables six reactions in parallel, electrodes of various materials and sizes, and vials from 1 to 20 ml.
The IKA ElectraSyn App (available for both iPhone and Android) enables reaction and CV experiment monitoring, data transmitting, and various other functions. ElectraSyn is a device that improves over time through regular software updates.
Scope of delivery
ElectraSyn 2.0 Package
Single vial holder
Single vial, 10 ml, complete
Electrodes (graphite) (2x)
Stir plate
$$$$$
Nominal voltage (input)
48 VDC
Current max. (input)
1500 mA
Voltage output (electrode)
30/10 V
Current output (electrode)
100 mA
Motor rating output
9 W
Speed range
50 - 1500 rpm
Setting accuracy speed
10 rpm
Stirring quantity max. per stirring position (H2O)