You have no items in your shopping cart
iScope
- Buy 2 and save 5%
iScope - A masterpiece in microscopy
The iScope is available in various configurations suitable for Life and Biomedical Sciences, high schools, universities but also for routine medical applications
Besides the brightfield contrast method, configurations for phase contrast, cardioid mirror darkfield, basic polarization and several epi- illumination sources for fluorescence applications can be used. iScope models with multi-heads are also available for teaching purposes
Check out the product video
Icons are used to indicate the several functions of a microscope.
Click and find more details about the meaning of each icon
Highlights
- EWF 10x/22 mm and EWF 10x/20 mm eyepieces
- Binocular and trinocular models
- Multihead and face-to-face dual head systems
- Optional tilting head
- Quintuple reversed nosepiece
- Plan, phase and darkfield illumination
- 187/230 x 140 mm rackless stage
- 3 W NeoLED™ Köhler illumination
- iCare sensor for energy saving
- CSS - Cable Storage System
iScope for Life Science (Finity models)
iScope for Life Science (Infinity ergonomic tilting head)
iScope for Life Science (Infinity models)
* Two tubes with diopter adjustments
iScope® for Life Science (Multihead systems)
iScope® for Life Science (Face-to-face dual head system)
iScope® for Life Science (Darkfield contrast application)
* Models for darkfield observation IS.1152-PLi/DF and IS.1153-PLi/DF are supplied with a state-of-the-art condenser equipped with reflective cardioid mirrors and a high powered 5 W LED. Together with a S100x objective with built-in iris diaphragm real 1000x magnification darkfield solution can be achieved. All other specifications are identical to models IS.1152-PLi and IS.1153-PLi. By adding the IS.9150 (darkfield cardioid mirror condenser with external 100-240 V power supply) and the 86.521 (S100x objective with built-in iris diaphragm) or the IS.7200-I (super contrast S100x infinity corrected IOS objective), an existing iScope brightfield microscope can be upgraded to darkfield as well.
$$$$$
EYEPIECES
• Extended Wide Field EWF plan 10x eyepieces with 20 mm field of view and adjustable diopter on the left eyepiece for finity corrected systems (Ø 23.2 mm tube)
• Extended Wide Field HWF plan 10x eyepieces with 22 mm field of view and adjustable diopter on both eyepieces for infinity corrected IOS plan and plan phase systems and adjustable diopter on the left tube for EPLi systems (Ø 30 mm tube)
HEAD
• Binocular and trinocular Siedentopf type heads with 30° inclined tubes. Interpupillary distance from 48 to 76 mm.
• The trinocular head of the Plan infinity corrected models (IS.1153-PLi) has an optical path selector (100:0 / 50:50) and ± 5 diopter adjustments on both Ø 30 mm tubes
• The trinocular head of the E-Plan infinity corrected models (IS.1153-EPLi) has a fixed built-in beamsplitter (50:50) and ± 5 diopter adjustment on the Ø 30 mm left tube
• The trinocular head of the E-plan finite models (IS.1153-EPL) has a fixed built-in 50:50 beamsplitter and one ± 5 diopter adjustment on the
Ø 23.2 mm left tube
• A unique rotating system allows the ergonomic positioning of both tubes in a high (431 mm) and in a low position (397 mm)
• The trinocular head comes with a Ø 23.2 mm photo port
ERGONOMICAL TILTING HEAD
Optional ergonomic 5 to 35° tilting head, interpupillary distance 48-75 mm and optional photo attachment with standard Ø 23.2 mm tube (only infinity corrected models and not suitable for multi head systems)
MULTIHEAD SYSTEM
The iScope® can be extended with a unique multihead system for in total two, three or five heads, allowing simultaneous observation of specimens. The central attachment is equipped with a joystick to move a green and red laser pointer across the entire field of view of all heads. Configurations with one, two or four additional viewing binocular heads, 30° inclined tubes and plan 4x, 10x, S40x, S100x oil immersion infinity corrected IOS objectives. All heads are equipped with extended wide field plan EWF 10x/22 mm eyepieces
(references: IS.1156-PLi-x, x = total number of heads)
IS.1156-PLi-9_DC.5000c
FACE-TO-FACE DUAL HEAD SYSTEM
• The iScope® can be supplied with two heads in a face-to-face configuration allowing simultaneous observation by two operators
• The 30 mm diameter tubes of the head are equipped with EWF 10x/20 mm eyepieces
• The main binocular head has one diopter adjustment, the second head has two adjustments
• Only available for the model with plan infinity corrected objectives (IS.1154-PLi)
• The face-to-face head is equipped with a 2-color laser pointer
OBJECTIVES
E-Plan EPL |
4x/0.10 |
10x/0.25 |
20x/0.40* |
S40x/0.65 |
S100x/1.25 oil |
||
E-Plan EPLi IOS |
4x/0.10 |
10x/0.25 |
S40x/0.65 |
S100x/1.25 oil |
|||
Plan PLi IOS |
2x/0.05 |
4x/0.10 |
10x/0.25 |
20x/0.40* |
S40x/0.65 |
S60x/0.85* |
S100x/1.25 oil |
Plan phase PLPH |
10x/0.25 |
20x/0.40 |
S40x/0.65 |
S100x/1.25 oil |
|||
Plan phase PLPHi IOS |
10x/0.25 |
20x/0.40 |
S40x/0.65 |
S100x/1.25 oil |
* optional
All optics are anti-fungus treated and anti-reflection coated for maximum light throughput
NOSEPIECE
Revolving quintuple reversed nosepiece for max. five objectives
STAGE
The iScope can be equipped with three types of stages:
• 156 x 138 mm stage equipped with integrated 79 x 52 mm X-Y mechanical stage
• 187/230 x 140 mm rackless stage equipped with double slide holder and integrated 79 x 52 mm X-Y mechanical stage. The iScope rackless stage has no protruding parts, enables more smooth movements and is safer
• 220 x 157 mm ceramic stage with integrated 75 x 50 mm X-Y mechanical stage protects with a very tough ceramic surface against marks and scratches. The surface also ensures stray light not to be reflected from the stage into the objective
The iScope can be supplied with a heating stage which can be set up to 50° Celsius by a PID temperature controller. Only available with new purchased microscopes. Higher temperatures can be achieved on special request
CONDENSERS WITH PHASE CONTRAST SLIDER
There is a choice of two optional NA. 1.25 phase contrast condenser sets with phase contrast sliders and plan phase contrast objectives. The first version one is comes with plan phase 10x and S40x objectives with matching slider, the second version comes with plan phase 20x and and S100x oil immersion objectives. Available for iScope 160mm and IOS infinity versions
All sets are supplied with centering telescope and green opaque filter
(Photo: IS.9162 - Phase contrast set)
CONDENSER FOR BRIGHTFIELD
The standard height adjustable Abbe N.A. 1.25 condenser for brightfield accepts sliders with phase annuli suitable for plan phase 10x/20x or S40x/S100x oil immersion IOS objectives for economical phase contrast. With magnification indication. A slider with a simple dark stop for darkfield up to 400x magnification is also available
CONDENSER FOR ZERNIKE PHASE CONTRAST
An optional height adjustable Zernike NA. 1.25 phase contrast disc condenser with plan phase 10/20/S40x and S100x oil immersion objectives and darkfield stop position for darkfield contrast up to 400x magnification. Supplied with alignment telescope and green filter
CONDENSER FOR DARKFIELD
A state-of-the-art condenser equipped with reflective cardioid mirrors, a high powered 5 W LED and a S100x objective with built-in iris diaphragm enable a real 1000x magnification darkfield solution
(Product data sheet iScope models for darkfield, see downloads)
FOCUSING
Coaxial coarse and fine adjustments, 200 graduations, 1 μm per graduation, 200 μm per rotation, total travel range is approximately 24 mm. Supplied with an adjustable rack stop to prevent damage to sample and objectives. The coarse adjustments are equipped with friction control
ILLUMINATION
3 W adjustable NeoLED diascopic illumination with internal 100-240 V power supply for brightfield and phase contrast models
The innovative NeoLED design offer larger apertures, allowing the optical system of the iScope microscope to produce images at higher resolutions, very close to the theoretical diffraction limit of the optics. Other benefits of the NeoLED is the low energy consumption, no heating and a long operating lifetime
The Köhler illumination on models with IOS plan and plan phase infinity corrected system provides high contrast and a maximum achievable resolving power of the optics. Also available for other models as option
ICARE SENSOR
The unique iCare Sensor is developed to avoid unnecessary loss of energy. The illumination of the microscope automatically switches off shortly after microscopists step away from their position
CSS - CABLE STORAGE SYSTEM
iScope allows users to easily insert the power cable into the back of the instrument, which enables easy storage. The integrated carrying grip at the back of the microscope ensures safe transportation of the microscope
PACKAGE CONTENT
Supplied with power cord, dust cover, a spare fuse, user manual and 5 ml immersion oil for models with S100x objective. All packed in polystyrene boxes
%%%%%
PB.5276 Microscoop-onderhoudsset, 16 onderdelen: schoonmaakpenseel, 6-delige schroevendraaiersset, blaasbalgje, 3-delige inbusset (1,5, 2, 2,5 mm), lensreinigingsvloeistof 20 ml, reinigingsdoek 140 x 140 mm, 100 stuks lenstissues, tube onderhoudsvet, 10 ml fles olie, verpakt in een overzichtelijke opbergdoos |
|
PB.5157-B Objectglaasjes 76 x 26 mm, wit glas, kanten geslepen. Een kant blauw. Per 50 stuks verpakt |
|
PB.5157-W Objectglaasjes 76 x 26 mm, wit glas, kanten geslepen. Per 50 stuks verpakt |
|
IS.5700 Ergonomische kantelbare kop 5 tot 35°. Voor iScope oneindig gecorrigeerde optische systemen |
|
IS.6010 EWF 10x/20 mm oculair, Ø 23,2 mm tubus |
|
IS.6010-C EWF 10x/20 mm oculair met kruisdraad, Ø 23,2 mm tubus |
|
IS.6010-P EWF 10x/20 mm oculair met aanwijsnaald, Ø 23.2 mm tubus |
|
IS.6010-CM EWF 10x/20 mm oculair met 10/100 micrometer en kruisdraad, Ø 23,2 mm tubus |
|
IS.6015 WF 15x/16 mm oculair, Ø 23,2 mm tubus |
|
IS.6020 WF 20x/12 mm oculair, Ø 23,2 mm tubus |
|
IS.6099 Paar oogschelpen, Ø 23,2 mm tubus |
|
IS.6210 EWF 10x/22 mm oculair, Ø 30 mm tubus |
|
IS.6210-C EWF 10x/22 mm oculair met 10/100 micrometer en kruisdraad, Ø 30 mm tubus |
|
IS.6210-P EWF 10x/22 mm oculair met 10/100 micrometer en kruisdraad, Ø 30 mm tubus |
|
IS.6210-CM EWF 10x/22 mm oculair met 10/100 micrometer en kruisdraad, Ø 30 mm tubus |
|
IS.6212 WF 12,5x/15 mm oculair, Ø 30 mm tubus |
|
IS.6215 WF 15x/16 mm oculair, Ø 30 mm tubus |
|
IS.6220 WF 20x/12 mm oculair, Ø 30 mm tubus |
|
IS.6299 Paar oogschelpen, Ø 30 mm tubus |
|
IS.7104 E-plan EPL 4x/0,10 objectief |
|
IS.7110 E-plan EPL 10x/0,25 objectief |
|
IS.7120 E-plan EPL 20x/0,40 objectief |
|
IS.7140 E-plan EPL S40x/0,65 objectief |
|
IS.7160 E-plan EPL S60x/0,85 objectief |
|
IS.7100 E-plan EPL S100x/1,25 objectief |
|
IS.7710 Plan PLPH 10x/0,25 fasecontrast objectief |
|
IS.7720 Plan PLPH 20x/0,40 fasecontrast objectief |
|
IS.7740 Plan PLPH S40x/0,65 fasecontrast objectief |
|
IS.7700 Plan PLPH S100x/1,25 fasecontrast objectief |
|
IS.8804 E-plan EPLi 4x/0,10 IOS oneindig gecorrigeerd objectief |
|
IS.8810 E-plan EPLi 10x/0,25 IOS oneindig gecorrigeerd objectief |
|
IS.8840 E-plan EPLi S40x/0,65 IOS oneindig gecorrigeerd objectief |
|
Click HERE for all accessories for IScope |