Informatie
MODELLEN LWD Plan fase 10x/20x/S40x objectieven 100 W Opvallende halogeenverlichting 10 W LED opvallende verlichting 100 W HBO fluorescentieverlichting
DI.3053‑PLPHFi  
DI.3053‑PLPHFi/HAL  

$$$$$

OCULAIRS
Een paar DIN HWF plan 10x/25 mm of 10x/22 mm oculairs met dioptrie-instellingen

KOP
Trinoculaire kop met 45° schuine tubussen. Instelbare oogafstand tussen 47 en 78 mm. De kop heeft een lichtwegverdeler van 100-0, 80/20 en 0/100

REVOLVER
Kogelgelagerde revolver voor zes objectieven. De revolver kan uitgerust worden met DIC-prisma's voor de 10x/20x en 40x objectieven

OBJECTIEVEN
• Hoognumerieke, oneindig gecorrigeerde semi-apochromatische Fluarex plan fase PLPHFi 10x/0,30, 20x/0,45, S40x/0,60 IOS objectieven met een lange werkafstand, maken de observatie van sub-cellulaire structuren mogelijk
• 4x/0,13 en 60x/0,70 IOS objectieven zijn ook beschikbaar (optioneel)
• De 20x, 40x en optioneel 60x objectieven zijn voorzien van een dekglascorrectiering voor een glasdikte van 0 tot 1,2 mm

Fluarex™ objectieven zijn vervaardigd van laag-absorbtieglas  
Fluarex™ is een handelsmerk van Euromex microscopen bv 
Alle optiek is behandeld tegen schimmel en heeft een anti-reflectie coating voor een maximale lichtopbrengst

TAFEL
Tafel 340 x 230 mm, voorzien van een X-Y kruistafel (130 x 85 mm).
Geleverd met:
•  Metalen opbjecthouder voor ø 38 mm kweekschaal
•  Metalen opbjecthouder voor ø 54 mm kweekschaal of 76 x 26 mm objectglaasje
•  Metalen opbjecthouder voor Multiwell-platen (127,76  x 85,48 mm) 
•  Metalen opbjecthouder voor Teraski-platen (83,3 x 58,0 mm)
•  Optioneel: universele kweekschaalhouder

CONDENSOR
Roterende N.A. 0,55 condensor met irisdiafragma. Werkafstand is 26 mm. Geleverd met fasecontrastringen voor 10x/20x, 40x en 60x objectieven, en DIC-prisma's voor de 10x/20x/40x en 60x objectieven. Drie filterhouders maken het plaatsen van Ø 38 mm filters in het optische pad mogelijk. De arm met condensor kan naar achteren hellen, voor goede toegang tot de tafel. Dit maakt het makkelijk plaatsen van grote objecten mogelijk, zoals cultuurflessen en Petri-schalen

VERGROTINGSWISSELAAR
Een lenswisselaar met een 1,5x lens zorgt voor intermediare vergrotingen van 1,5 keer de standaard objectiefvergroting. Schakelen tussen 20x en 30x of 40 en 60, of tussen 60x en 90x vergrotingen kan gedaan worden zonder weer scherp te moeten stellen op het preparaat

Delphi-X_Inverso_Detail-3  Delphi-X_Inverso_Detail-4

6-positie fluorescentie-filtersetwiel en 1,5 vergrotingswisselaar

FLUORESCENTIEAANVULLING
De Delphi-X Inverso vooor fluorescentiemicroscopie wordt geleverd met een 6-positiie fluorescentie-filtersetwiel en met twee fluorescentiefiltersets voor blauwe en groene excitatie (DI.9745 en DI.9746). Andere filtersets zijn optioneel

DI.9745_grafiek

DI.9745 Blue excitation, EX 460-495 DM 505 EM 510 long pass

 

DI.9746_grafiek

DI.9746 Green excitation, EX 510-550 DM 570 EM 575 long pass

DI.9747_grafiek

DI.9747 Violet excitation, EX 400-410 DM 455 EM 460 Long pass

DI.9748_grafiek

DI.9748 Ultra violet excitation, EX 330-385 DM 410 EM 420 Long pass


DI.9750.TRITC_grafiek

DI.9750.TRITC Green excitation, EX 528-553 DM 565 EM 578-633 band pass

DI.9750.FITC_grafiek

DI.9750.FITC Blue excitation, EX 460-495 DM 505 EM 510-550 band pass

DI.9750.DAPI_grafiek

DI.9750.DAPI UV excitation, EX 360-390 DM 415 EM 435-485 band pass

DI.9750.R_grafiek

DI.9750.R Red excitation, EX 620-650 DM 660 EM 670-750 band pass

SCHERPSTELREGELING
Coaxiale 10 mm grof- en fijnregelknoppen, 1 μm precisie en stroefheidsregeling

VERLICHTING
Fluorescentieverlichting met een 100 W kwikdamplamp met een externe 100-240 V voeding. Doorvallende 10 W LED of 100 W halogeenverlichting en interne voeding. Zekeringhouder 3,15 A / 250 V

VERPAKKING
Geleverd met metalen objecthouder voor Ø 38 mm celkweekschalen en een metalen objecthouder voor Ø 54 mm celkweekschalen en 76 x 26 mm objectglaasjes, metalen objecthouder voor Multiwell-platen, metalen objecthouder voor Teraski-platen, blauwe en groene interferentiefilters (Ø 45 mm), netsnoer, stofhoes, groenfilter, centreertelescoop en handleiding

%%%%%

No image DI.6010
Super wide field SWF 10x/22 mm focusable eyepiece for Delphi-X Inverso, 30 mm diameter tube
No image DI.6210
Super wide field SWF 10x/22 mm focusable eyepiece for Delphi-X Inverso, 30 mm diameter tube
No image DI.6012
Wide field WF 12.5x/17.5 mm eyepiece for Ø 30 mm tube for Delphi-X Inverso
No image DI.6015
Wide field WF 15x/16 mm eyepiece for Ø 30 mm tube for Delphi-X Inverso
No image DI.6020
Wide field WF 20x/12 mm eyepiece for Ø 30 mm tube for Delphi-X Inverso
No image DI.6099-L
Eyeshade for eyepieces
No image DI.8704
Infinity Plan Semi-Apochromatic Phase contrast PLPHFi-Apo 4x/0.13 objective, working distance 16,8 mm. Cover glass correction 1.2 mm
No image DI.8710
Infinity Plan Semi-Apochromatic Phase contrast PLPHFi-Apo 10x/0.30 objective. Working distance 10.2 mm. Cover glass correction 1.2 mm
No image DI.8720
Infinity Plan Semi-Apochromatic Phase contrast PLPHFi-Apo 20x/0.45 objective with collar ring for adjustment of working distance between 7.5 to 8.8 mm. Cover glass correction 1.2 mm
No image DI.8740
Infinity Plan Semi-Apochromatic Phase contrast PLPHFi-Apo 40x/0.60 objective with collar ring for adjustment of working distance between 3 to 4.4 mm. Cover glass correction 1.2 mm
No image DI.9690-10
DIC prism for rotating disc condenser for Life Science Delphi Inverso models. To be used with Plan Semi-Apo 10x objective
No image DI.9690-20
DIC prism for rotating disc condenser for Life Science Delphi Inverso models. To be used with Plan Semi-Apo 20x objective
No image DI.9690-40
DIC prism for rotating disc condenser for Life Science Delphi Inverso models. To be used with Plan Semi-Apo 40x objective
No image DI.9695
DIC polarization filter for transmitted light
No image DI.9200-6
Fluorescence attachment, 6-positions, UV shield; 100 W HBO mercury vapor lamp, with collimating lens, with external PSU BUT without objectives, without filter sets and without empty cubes
No image DI.9745-6
Standard filter set for Blue excitation EX 460-495 nm (BP) DM 505 EM 510 nm (LP). Needs empty cube
No image DI.9746-6
Standard filter set for green excitation EX 510-550 nm (BP) DM 570 EM 575 (LP) Needs empty cube
No image DI.9747-6
Standard filter set for Violet excitation EX 400-410 nm (BP) DM 455 EM 460 (LP) Needs empty cube
No image DI.9748-6
Standard filter set for UV excitation EX 330-385 nm (BP) DM 410 EM 420 (LP) Needs empty cube
No image DI.9749
Empty cube for Delphi-X Observer Fluorescence attachment
DI.9750.19000
Fluorescence filter set EX375 (BP28: 361-389 nm) DM415 (LP) EM435 (LP) optimized for UV/DAPI, Calcofluor White. Needs empty filter block
DI.9750.19006
Fluorescence filter set EX560 (BP40: 540-580 nm) DM600 (LP) EM610 (LP) optimized for FM 4-64, Turbo FP650. Needs empty filter block
DI.9750.19008
Fluorescence filter set EX450 (BP50: 425-475 nm) DM485 (LP) EM495 (LP) optimized for Auramine Longpass. Needs empty filter block
DI.9750.19010
Fluorescence filter set EX480 (BP30: 465-495 nm) DM505 (LP) EM600 (LP) optimized for FM 1-43 / 4-64 , Pulsar 650 and Chlorophyll Longpass. Needs empty filter block
DI.9750.19011
Fluorescence filter set EX405 (BP30: 390-420 nm) DM505 (LP) EM450 (LP) optimized for Coumarin and Pacific Blue Longpass. Needs empty filter block
DI.9750.19012
Fluorescence filter set EX375 (BP28: 361-389 nm) DM415 (LP) EM515 (LP) optimized for FluoroGold and CalcoFluor White Longpass. Needs empty filter block
DI.9750.39000
Fluorescence filter set EX375 (BP28: 361-389 nm) DM415 (LP) EM460 (BP50: 435-485 nm) optimized for DAPI, Hoechst, AlexaFluor 350. Needs empty filter block
DI.9750.39001
Fluorescence filter set EX435 (BP20: 425-445 nm) DM455 (LP) EM480 (BP30: 465-495 nm) optimized for AmCyan, Atto 425, Cerulean, CFP, ECFP fluorophore. Needs empty filter block IS.9749
DI.9750.39002
Fluorescence filter set EX480 (BP30: 465-495 nm) DM505(LP) EM535 (BP40: 515-555 nm) optimized for Acridine Orange + DNA, Alexa Fluor 488™, Atto 488, Azami Green, BODIPY FL/pH7.2, Calcein, Calcium, Green™-1, Cy2™, DiO, DyLight 488, EGFP, Emerald, GFP, FAM, FITC, Fluo-4, GFP, LysoTracker Green/pH 5.2, MitoTracker Green, FM/MeOH, mWasabi, Oregon Green™ 488, SYBR® Green I, SYTO 9/DNA, ZsGreen fluorophore. Needs empty filter block
DI.9750.39003
Fluorescence filter set EX495 (BP20: 485-505 nm) DM515 (LP) EM540 (BP30: 525-555 nm) optimized for Alexa Fluor 514™, Citrine, EYFP/pH 7, F/lAsH-CCPFCC, mCitrine, Oregon Green™ 514, Rhodamine 123, Topaz. Needs empty filter block
DI.9750.39004
Fluorescence filter set EX540 (BP25: 528-553 nm) DM565 (LP) EM605 (BP55: 578-633 nm) optimized for Alexa Fluor 546™, Alexa Fluor 555™, Atto 550, CAL, Fluor® Red 590, Cy3™, DiI, DsRed, DyLight 549, MitoTracker Orange/MeOH, Resorufin, Rhod-2, TagRFP, TAMRA tdTomato, Tetramethylrhodamine, isothiocyanate, TRITC. Needs empty filter block
DI.9750.39005
Fluorescence filter set EX540 (BP25: 528-552 nm) DM565 (LP) EM 620 (BP60: 590-650 nm) optimized for TRITC-red-shifted, Ethidium homidimer-1/DNA, Propidium Iodide. Needs empty filter block
DI.9750.39007
Fluorescence filter set EX620 (BP50: 595-645 nm) DM655 (LP) EM 690 (BP50: 665-715 nm) optimized for Alexa Fluor 647™, Allophycocyanin (APC), Atto 647N, Cy5™, DiD, Draq5, DyLight 649, MitoTracker Deep Red 633/MeOH, Nile Blue, Quasar® 670, SYTO® 60, TO-PRO™-3. Needs empty filter block
DI.9750.39008
Fluorescence filter set EX420 (BP40: 400-440) DM455 (LP) EM 535 (BP40: 515-555) optimized for Lucifer Yellow/Tetracycline/AlexaFluor 430. Needs empty filter block
DI.9750.39009
Fluorescence filter set EX480 (BP30: 465-495) DM505 (LP) EM 620 (BP60: 590-650) for Acridine Orange + RNA, Di-8-ANEPPS, non-radiometric, DiA, Ethidium Bromide, FM™ 1-43, LysoTracker Yellow HCK-123, Pulsar™ 650. Needs empty filter block
DI.9750.39010
Fluorescence filter set EX560 (BP40: 540-580) DM600 (LP) EM635 (BP60: 615-665) optimized for Texas Red, mCherry, AlexaFuor 594. Needs empty filter block IS.9749
DI.9750.49000
Fluorescence filter set EX350 (BP50: 325-375) DM400 (LP) EM460 (BP50: 435-485) optimized for Texas Red, mCherry, AlexaFuor 594. Needs empty filter block IS.9749
No image DI.9810
C-mount 1x adapter voor Delphi-X Inverso microscoop
No image DI.9840
C-mount adapter met hoge resolutie 0.40x objectief voor 1/3 inch C-mount camera
No image DI.9850
C-mount adapter met hoge resolutie 0.50x objectief voor 1/2 inch C-mount camera
Door het gebruiken van onze website, ga je akkoord met het gebruik van cookies om onze website te verbeteren. Dit bericht verbergen Meer over cookies »